If WiFi network is to hold Buddha's feet temporarily, before the newly renovated apartment is delivered to the tenant——The weak cell left an empty spot, the network was not in every room, the POPE switch wasn't set up, and it was only when we got a lease to put on AP.——Finally, either the routing is ugly and the tenant complains, or the signal coverage is uneven and there is no signal in the top corners.
The apartment WiFi network billing system is not a device that was delivered on the day it entered. It needs to be pre-enacted in parallel with the renovation phase: weak power cell positions, grid routing, AP points, POPE switches, all set up during the renovation of the drawings.
Apartment WiFi network billing systemWhich locations to leave during the renovation phase?
The first is a weak electric room or a weak electrical box. A weak power exchange and an AP meeting point are needed for each floor of the central apartment building; a small, decentralized flat has a weak cell on the first floor or every other floor. This location should be ventilated, powered and far from the powerful ones. The V7 POPE switch is not large, but it requires 220V power and heat radiating space, with plugs and ventilation vents to be made.
The second is the network. From the weak cell to each room or public area, six types of wire are laid. The top AP grid goes from the weak cell to the corridor ceiling and the panel AP netline goes to the door of the room. The POPE switch provides both power and data to AP through this web line without additional power.
Apex APs are suitable for corridors, public areas, open rooms; panel APs are appropriate for individual rooms and have their original net entrances. One room is a panel AP with even signal coverage; corridor topsAP covers the public area. The number of points is based on household drawings, and not until the corner is filled without a signal after the renovation.
Apartment WiFi network billing systemWhere did you put it?
NATSHEL_AUTH_GATEWAY is the core equipment of the system and is responsible for Portal re-direction, user certification, strategy distribution. In new apartments, NATSHEL_AUTH_GATEWAY is usually located in a machine room or a weak electrical room on the first floor, together with a core switch, an export router. V7 Authentication Gateway is in a network export position where all online traffic is certified and billed.
If the apartment is small, it can be in fat AP mode and no separate NATSHEL_AUTH_GATEWAY——Fat AP itself is a local Portal and third-party RADIUS authentication function, which directly connects to the cloud counter.
The cloud billing platform does not itself need to place the server on the apartment site. V7 Unified Authentication & Billing Platform is deployed on the cloud mainframe, and only AP, POE switchboards, Authentication Gateway (if you use a gateway mode), connect to the cloud over the Internet. This means that there is no need to keep the server's lockers in the delivery room, as long as network exports are stable.
Apartment WiFi network billing systemHow do you get in?
Initial renovation: location of the weak electrical booths, netting and pre-seting of AP points.
The equipment will be equipped for electrical testing.
Two weeks before delivery: cloud billing platform configuration. V7 platform build user groups, a meal package, Portal page and payment for the matching micromails.
Apartment WiFi network billing systemWhat are the tests to be performed before delivery?
Three things are to be measured before delivery: signal coverage, authentication process, billing shut-down. Signal coverage is a double walk in every room, cell phone strength, dead end APs; certification process is a tenant's perspective.——WiFi, Play Portal, register, pick-up package, pay, access to the Internet and no credit at all; billing closed rings run through a full process from payment until certification release to termination when due.
The system is automatically released on MAC, after the tenant has certified it. Whether the mobile phone can be recertified or restored to the plant's installation will also be tested. These tests are done before delivery, and the tenant's access to the Internet on the day of the lease is good, and there will be no extra renting.
There is also a point that can be easily ignored: heat evaporation and dust protection between weak power cells. The POPE switch and Authentication Gateway run 24 hours, although not very expensive, and the weak electrical box is so dense that it can be overheated by wind during summer. The weak battery should leave vents when decorated, and the switch should not be sealed in a fully closed cabinet. AP will also be installed to avoid chandeliers, central air conditioning vents, and these signal shielding and heat sources.
Also, AP installation is located in a position to avoid the shield. The top AP is placed in the hallway to cover both sides of the room evenly; if it is mounted on the corner or blocked by fire sprays, the next room signal is clearly weak. The panel AP is installed at the door entrance to the room, not behind the bedside or behind the TV, and these are metal-protected. These details are set during the renovation phase and the tenant will not reflect when delivered."I have no signal in the corner of my room."。
The most taboo thing about the new apartment WiFi is that it's a very dangerous place to go."The team doesn't know the network. The team doesn't know how to decorate it."The location of the weak electrical booths, the wiring and the AP position is confirmed by the network scheme at the stage of renovation drawings, without waiting for the completion of the renovation to be repaired. Pre-encumbrances are right, with the APA plug and platform pairing available; they are wrongly pre-arranged, and the cost of later rework is much greater than planned. In the construction sequence, the network cabling line is synchronized with the utility walkover, and the AP installation is completed after the top is finished, before the wall is painted, and the final platform configuration and testing is done before the furniture is entered. Each step of the card point is stuck, the delivery day network is connected and not used for rent side repairs.